Review




Structured Review

Molecular Dynamics Inc phosphoimager plates
Phosphoimager Plates, supplied by Molecular Dynamics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/phosphorimager+plate/pmc06140716-226-0-4
Average 90 stars, based on 1 article reviews
phosphoimager plates - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

Software:

Article Title: Aminoglycoside antibiotics and methods of using same
Article Snippet: Following the translation, the samples were analyzed by electrophoresis on 4-20% SDS mini-gels (Invitrogen) for 1.5 h at 120V. .. Gels were fixed with 40% methanol/10% acetic acid and exposed to Molecular Dynamics phosphoimager plates, which were read on a Personal FX phosphoimager (Bio-Rad) and quantitated using QuantityOneTM software. .. E. coli (ATCC 25922) and P. aeruginosa (ATCC 27853) (BD Bioscience) were inoculated in 3 mL of the medium 2 (U.S. Pharmacopia), containing 6 g peptone, 3 g yeast extract and 1.5 g beef extract per 1 L, pH 6.6, and were grown in a shaker for 6 h at 37° C. until an OD 560=0.6-0.8 was reached.

Article Title: Aminoglycoside antibiotics and methods of using same
Article Snippet: .. The results were visualized by exposing the wet gels to Molecular Dynamics phosphoimager plates, which were read on a Personal FX phosphoimager (Bio-Rad) and quantitated using QuantityOneTM software. .. In a typical experiment, 10 μL of 10 mM HEPES buffer, pH 7.0, containing 50 mM KCl, were incubated with 100 ng of 5′-32P-labeled D- or L-RNA oligonucleotide in the presence of of 0.5 μg tRNA and varying concentrations of D-, L-neamine or neomycin B at room temperature for 5 min. One μL of neat dimethyl sulfate (DMS, Sigma) was added to the samples.

other:

Article Title: Re-evaluation of neuronal P2X7 expression using novel mouse models and a P2X7-specific nanobody
Article Snippet: Autoradiographic analysis (Phosphoimager plates, Molecular Dynamics) specifically detected the expected hybridization signals at 5277 bp (BAC transgene) and 4561 bp (endogenous P2rx7).

Article Title: Re-evaluation of neuronal P2X7 expression using novel mouse models and a P2X7-specific nanobody
Article Snippet: Autoradiographic analysis (Phosphoimager plates, Molecular Dynamics) specifically detected the expected hybridization signals at 5277 bp (BAC transgene) and 4561 bp (endogenous P2rx7 ).

Electrophoresis:

Article Title: Molecular genetic responses to lysergic acid diethylamide include transcriptional activation of MAP kinase phosphatase-1, C/EBP-beta and ILAD-1, a novel gene with homology to arrestins.
Article Snippet: .. After electrophoresis, gels were dried on Whatman paper and exposed to phosphoimager plates (Molecular Dynamics, Sunnyvale, CA, USA). .. Bands were visualized using either a Molecular Dynamics 445 SI Phosphoimager or Typhoon 9400 Phosphoimager (Amersham Biosciences).



Similar Products

86
Cytiva Europe phosphoimager plate
Phosphoimager Plate, supplied by Cytiva Europe, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/pm35049071-70-43-45
Average 86 stars, based on 1 article reviews
phosphoimager plate - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
FUJIFILM phosphoimaging plates (bas-ip)
Phosphoimaging Plates (Bas Ip), supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/las+3000/bio_rxiv__2024__05__28__596144-174-46-50
Average 90 stars, based on 1 article reviews
phosphoimaging plates (bas-ip) - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
FUJIFILM bas-mp ip phosphoimager plate
Bas Mp Ip Phosphoimager Plate, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/las+3000/pmc09479745-296-14-18
Average 90 stars, based on 1 article reviews
bas-mp ip phosphoimager plate - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
FUJIFILM phosphoimaging plate fla-7000
Phosphoimaging Plate Fla 7000, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/las+3000/pmc07527401-165-28-31
Average 90 stars, based on 1 article reviews
phosphoimaging plate fla-7000 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
FUJIFILM phosphoimager plates fujifilm
Phosphoimager Plates Fujifilm, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/las+3000/pmc06377479__pnas__1814380116__sapp-21-0-2
Average 90 stars, based on 1 article reviews
phosphoimager plates fujifilm - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Molecular Dynamics Inc phosphoimager plates
Phosphoimager Plates, supplied by Molecular Dynamics Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/phosphorimager+plate/pmc06140716-226-0-4
Average 90 stars, based on 1 article reviews
phosphoimager plates - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
FUJIFILM phosphoimaging plate bas-iiis
Ex vivo autoradiography and histochemical imaging of C6 glioma-bearing rat brains. After PET imaging using L- ( a ) or D- 18 F-FBPA ( b ), rats were sacrificed under anesthesia, the brain was excised and sliced at a thickness of 2 mm, and the slices were then exposed to a <t>phosphoimaging</t> plate in order to calculate the target tumor (glioma) to non-target (normal) ratios of L- and D- 18 F-FBPA ( c ). # P < 0.05 vs. L-isomer. The brain excised from another rat bearing C6 glioma was fixed in 4% neutral-buffered formalin; samples were embedded in paraffin, sliced at a thickness of 30 μm, and stained with HE ( d )
Phosphoimaging Plate Bas Iiis, supplied by FUJIFILM, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/phosphoimager+plates/las+3000/pmc05999598-92-5-8
Average 90 stars, based on 1 article reviews
phosphoimaging plate bas-iiis - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


Ex vivo autoradiography and histochemical imaging of C6 glioma-bearing rat brains. After PET imaging using L- ( a ) or D- 18 F-FBPA ( b ), rats were sacrificed under anesthesia, the brain was excised and sliced at a thickness of 2 mm, and the slices were then exposed to a phosphoimaging plate in order to calculate the target tumor (glioma) to non-target (normal) ratios of L- and D- 18 F-FBPA ( c ). # P < 0.05 vs. L-isomer. The brain excised from another rat bearing C6 glioma was fixed in 4% neutral-buffered formalin; samples were embedded in paraffin, sliced at a thickness of 30 μm, and stained with HE ( d )

Journal: EJNMMI Research

Article Title: Evaluation of D-isomers of 4-borono-2- 18 F-fluoro-phenylalanine and O - 11 C-methyl-tyrosine as brain tumor imaging agents: a comparative PET study with their L-isomers in rat brain glioma

doi: 10.1186/s13550-018-0404-6

Figure Lengend Snippet: Ex vivo autoradiography and histochemical imaging of C6 glioma-bearing rat brains. After PET imaging using L- ( a ) or D- 18 F-FBPA ( b ), rats were sacrificed under anesthesia, the brain was excised and sliced at a thickness of 2 mm, and the slices were then exposed to a phosphoimaging plate in order to calculate the target tumor (glioma) to non-target (normal) ratios of L- and D- 18 F-FBPA ( c ). # P < 0.05 vs. L-isomer. The brain excised from another rat bearing C6 glioma was fixed in 4% neutral-buffered formalin; samples were embedded in paraffin, sliced at a thickness of 30 μm, and stained with HE ( d )

Article Snippet: Slices were transferred to a phosphoimaging plate (BAS-IIIs, Fuji film) for 10 min of exposure with an authentic standard radioactivity source.

Techniques: Ex Vivo, Autoradiography, Imaging, Staining